Dynamical modelling and cost optimization of a 5G base station
The base station''s average energy consumption during a certain time period has been estimated. A range of optimization approaches, namely PSO, ABC, and GA, have been
In the optimal configuration of energy storage in 5G base stations, long-term planning and short-term operation of the energy storage are interconnected. Therefore, a two-layer optimization model was established to optimize the comprehensive benefits of energy storage planning and operation.
A multi-base station cooperative system composed of 5G acer stations was considered as the research object, and the outer goal was to maximize the net profit over the complete life cycle of the energy storage. Furthermore, the power and capacity of the energy storage configuration were optimized.
The inner goal included the sleep mechanism of the base station, and the optimization of the energy storage charging and discharging strategy, for minimizing the daily electricity expenditure of the 5G base station system.
Model of Base Station Power System The key equipment in 5G base stations are the baseband unit (BBU) and active antenna unit (AAU), both of which are direct current loads. The power of AAU contributes to roughly 80% of the overall communication system power and is highly dependent on the communication volume .